Tag Archives: immersion heater

Friday 16th December 2011 – JULIE’S MUM …

loaded caliburn ford transit… said to me that I could fit a few extra things in Caliburn, because her son in law (Rob) had told her that it would be quite empty coming back.

Well, absolutely. As you can see.

Shall we run through all of the stuff that isn’t there? Like no scaffolding for a start? No rolls of insulation?

As Clare said when she saw the photograph “it’s a good job that I forgot to ask you about the three-piece suite”. Plenty of room for that.

I left my hotel fairly early and did another trip around the supermarkets and tool supply places like Screwfix and Toolstation, all for stuff that I had forgotten.

Another trip down to my storage box and collect the last of the stuff that I had ordered. And my luck was in again – I managed to source another Ford Transit wheel for Caliburn’s winter tyres.

Northampton was next, and Michael very kindly sorted out a 98-litre immersion heater for me from his plumbing supplies place. This is for the solar hot water at home.

Rosemary had asked me to call at a place in London for 7 rolls of this space-blanket roof insulation, and then back out to Luton for Rob and Julie’s stuff.

No wonder I was exhausted.

I made it down to Pompey – Portsmouth – with time to spare – which surprised me totally. Enough time in fact to go to the chippy for another huge dollop of beans and chips all smothered in malt vinegar, just like the evening that I arrived, which seemed like a year ago.

Now I’m sitting in the queue for the ferry, which leaves at 23:59. I hope that there’s a nice corner for me to curl up into. I’m exhausted!

Monday 3rd October 2011 – WELL, IT’S BACK …

… to the daily grind now. Or, at least, it should have been, except that at instead of the early night that I had promised myself,I was still wide awake at 05:00. Sleep issues again – it must be my guilty conscience.

Obviously, 08:15 never happened and it was about 10:50 when I heaved myself out of my stinking pit ready to face the world.

This morning I spent writing up my notes for the match yesterday. I’m amazed about how much I wrote and it’s probably going to take me all week to do the web page for it. But I need to exert myself and not let things drag around like I have been doing.

This afternoon I moved a few things around on the car park and managed to get at the immersion heaters under the tarpaulin. There’s a newish 50-litre tank there that Bill gave me because it has a leak in it somewhere so I’ve connected it all up to all kinds of pipes so that I can fill it with water and then close it off. I’ll leave it like that for a day or so to see if I can see where it’s leaking from. Then I can fix the leak, fit a 12-volt element in it and then use it in the lean-to as the new dump load.

>A pleasant surprise at the Anglo-French Group tonight where we had two new members. Peter brought his ladyfriend along to take part, and Nan turned up, seeing as she has now moved to la Cellette. we had a really good time as well and we were all quite animated. It’s nice to see that kind of thing happening.

But that’s it basically and I really am going to be going to bed in a minute. These late nights are catching up on me and I need to be up early tomorrow.

Tuesday 11th January 2011 – I made some slow progress today

The plasterboarding on the two outside walls in the bedroom is only up to 2.50 metres whereas the room itself is about 2.78. What I’ve done in the gaps is to run all of the conduit and trunking for the electric cables, as you may have already seen. For the side wall, I can make up the difference by building up with some plasterboard strips and then put a plank of 4.50 x 10 over the trunking so that it looks like a beam (the real outer beam is of course hidden in the 80mm of insulation on the wall).

But a big hunt around didn’t uncover a suitable plank and so I need to go to the sawmill, unless anyone has a suitable beam lying around anywhere. Of course I could use two smaller planks but it would look silly. Whoever heard of a beam with a join in it?

electrical wiring bedroom ceiling les guis virlet puy de dome franceFor the front wall I’ll be using plasterboard with 20mm of insulation behind it and cut to a castellated shape to fit between the beams. And so today I’ve been fitting the longitudinal laths between the beams so that I can infill between the beams with tongue-and-grooving to hide the 60mm of insulation there, and then I fitted some stand-off brackets on the front wall to take the plasterboard. This is all very finicky work and as you know I don’t do finicky and so it’s really slowwwwww. But it’s progress all the same

I’ve also made a change at the top of the stairs just here. I had a huge old cardboard box that I had opened out and used as an insulated wall covering, to cover over the back of the plasterboarding into my attic (I can’t cover it properly as I’ll be running the water pipes down there in due course). But a bit of measuring up revealed that the offcuts of the space-blanket insulation from when I did the walls of the bedroom – they would be a perfect fit and so I took the box off and redid it. And it’s cut down all the draughts that came in through there. But the firewood doesn’t like it and just now one of the boxes of firewood went crashing down the stairs decanting its contents all over the place.

This afternoon I braved the Hound of the Baskervilles and went round to Bill’s. He had a 100-litre immersion heater that was fairly new and which he was giving away to a good home. It has a slight leak around the electriclty plate, but that’s no problem for me as I’ll be taking it off anyway and fitting my own with one of my 12-volt elements.

He also had a small 50-litre immersion heater as well that was looking for a good home. And that got me thinking. Heater elements are what is known as “resistance elements” and so will work with any kind of voltage. And so with 50 litres, which isn’t a lot of water but more than I ever need, I could use it as the dump load for the set-up in the barn and run my 12-volt surplus current into it directly. With the element rated at 220 volts and with me putting 13.4 volts through it, I’d be getting only 0.06 of the power output (if the element is rated at 1200 watts I’d be getting about 75 watts – if it’s rated at an unlikely 3kw I would be getting about 180 watts) but 50 litres in a proper insulated tank won’t need all that much power to warm up. What I will need to do is to find a way of fitting a temperature sensor in there so that I can keep an eye on the temperature.

Of course, it might not work. But the whole idea is that it’s an experiment and we can see what happens.

But I had a bad night last night. I woke up at about 04:00 with a nightmare (a long time since I’ve had one of those) and I couldn’t go back to sleep afterwards. I’ll be having an early night.

Saturday 1st January 2011 – HAPPY NEW YEAR!

And quite right too!

Wishing everyone the compliments of the season, and me too because regular readers of this rubbish will realise that it’s been a long time since I’ve had any.

it’s a Bank Holiday today and so that means a lie-in, and then a day of leisure where I do as little as possible.

Not quite though, because François was having a get-together and because regular readers of this rubbish tell me that I need to get out more often, I decided to go. It never does anyone any harm to socialise – including me.

The usual crowd was there of course – not very inspiring unfortunately. But nevertheless I’m glad that I went because Bill was there and at least I can have a good chat or two with him.

The good news to come out of that is that Bill has offered me an immersion heater – 100 litres – that he’s just taken out of his house. I’ve been looking for a small one like this for quite a while.

If I can change the element from 230 volt to 12 volt then this will go nicely in the barn to use as a dump load for the excess solar energy, assuming that we ever get any more decent sunshine.

Not sure when that might be.

Thursday 26th August 2010 – Now this is exciting.

12 volt water heater barn les guis virlet puy de dome franceI told you a few days ago that Simon had an old 12-volt water boiler in his van but he had taken it out and replaced it with an Econowash unit like I have in Caliburn.

Anyway he very kindly donated it to the cause and this afternoon I fitted it in the barn wired up to another charge controller.

I don’t use much electricity out of the barn right now and the batteries in there are fully-charged by 09:30 most mornings and that’s quite a waste of power. So I’ve wired up a charge controller to act as a dump load and I’ve connected this boiler into there.

It’s only 2.5 litres and that isn’t very much at all but running the surplus current from 370 watts of solar panels into there should get that water pretty hot on most days. It’s going to be an interesting experiment anyway and it was really nice of Simon to donate it.

home made 12 volt immersion heater les guis virlet puy de dome franceBut what else I have been doing today is to make my immersion heater for the house. And here it is.

it’s a 30-litre chemical drum and I cut the top off it so that I could get inside it. I’ve screwed in one of my 500-watt 12-volt elements, the one that I had floating on a pontoon in that large bucket. That’s right at the bottom in a horizontal plane.

I then mounted a tap into the container – that’s mounted higher than the element so that the element will never run dry.

Once they were all fitted and sealed in I fitted a connecting ring made out of old tin cans pop-riveted onto the top of the bottom half and then slid the top half over the top of that. And then I wired it in.

Once I’m sure that it’s working I’m going to seal up the joint with some waterproof tape and then wrap it in rolls of insulation to keep the water warm. I’m thoroughly intrigued to see what this might produce. 20-odd degrees above the ambient temperature in an open bucket with 50 litres of  water – so what will 30 litres of water in a sealed and insulated container give me?

It’s exciting stuff.

oil filled water heater les guis virlet puy de dome franceIn the winter of course I will be using any surplus energy to run the oil-filled heater – the one that I bought earlier this year – in the attic. I had some good results from that last winter and if we mount this wind turbine when I come back from Canada things should be even better.

And if the results from the other water boiler are positive then I can put this one in the barn in the winter and see what that brings.

But what with one thing and another, things are looking quite positive around here these days and I feel like I’m making enormous progress.