{"id":632,"date":"2011-01-11T23:30:00","date_gmt":"2011-01-11T23:30:00","guid":{"rendered":"http:\/\/lesguis.com\/wp\/?p=632"},"modified":"2016-05-12T07:37:53","modified_gmt":"2016-05-12T07:37:53","slug":"i-made-some-slow-progress-today","status":"publish","type":"post","link":"https:\/\/lesguis.com\/wp\/?p=632","title":{"rendered":"Tuesday 11th January 2011 &#8211; I made some slow progress today"},"content":{"rendered":"<p>The plasterboarding on the two outside walls in the bedroom is only up to 2.50 metres whereas the room itself is about 2.78. What I&#8217;ve done in the gaps is to run all of the conduit and trunking for the electric cables, as you may have already seen. For the side wall, I can make up the difference by building up with some plasterboard strips and then put a plank of 4.50 x 10 over the trunking so that it looks like a beam (the real outer beam is of course hidden in the 80mm of insulation on the wall).<\/p>\n<p>But a big hunt around didn&#8217;t uncover a suitable plank and so I need to go to the sawmill, unless anyone has a suitable beam lying around anywhere. Of course I could use two smaller planks but it would look silly. Whoever heard of a beam with a join in it?<\/p>\n<p><a href=\"http:\/\/www.lesguis.com\/images\/1101\/1101019.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"http:\/\/www.lesguis.com\/images\/1101\/1101019.jpg\" alt=\"electrical wiring bedroom ceiling les guis virlet puy de dome france\" width=\"300\" height=\"204\"\/><\/a>For the front wall I&#8217;ll be using plasterboard with 20mm of insulation behind it and cut to a castellated shape to fit between the beams. And so today I&#8217;ve been fitting the longitudinal laths between the beams so that I can infill between the beams with tongue-and-grooving to hide the 60mm of insulation there, and then I fitted some stand-off brackets on the front wall to take the plasterboard. This is all very finicky work and as you know I don&#8217;t do finicky and so it&#8217;s really slowwwwww. But it&#8217;s progress all the same<br \/>\n<br clear=\"both\"><\/p>\n<p>I&#8217;ve also made a change at the top of the stairs just here. I had a huge old cardboard box that I had opened out and used as an insulated wall covering, to cover over the back of the plasterboarding into my attic (I can&#8217;t cover it properly as I&#8217;ll be running the water pipes down there in due course). But a bit of measuring up revealed that the offcuts of the space-blanket insulation from when I did the walls of the bedroom &#8211; they would be a perfect fit and so I took the box off and redid it. And it&#8217;s cut down all the draughts that came in through there. But the firewood doesn&#8217;t like it and just now one of the boxes of firewood went crashing down the stairs decanting its contents all over the place.<\/p>\n<p>This afternoon I braved the Hound of the Baskervilles and went round to Bill&#8217;s. He had a 100-litre immersion heater that was fairly new and which he was giving away to a good home. It has a slight leak around the electriclty plate, but that&#8217;s no problem for me as I&#8217;ll be taking it off anyway and fitting my own with one of my 12-volt elements.<\/p>\n<p>He also had a small 50-litre immersion heater as well that was looking for a good home. And that got me thinking. Heater elements are what is known as &#8220;resistance elements&#8221; and so will work with any kind of voltage. And so with 50 litres, which isn&#8217;t a lot of water but more than I ever need, I could use it as the dump load for the set-up in the barn and run my 12-volt surplus current into it directly. With the element rated at 220 volts and with me putting 13.4 volts through it, I&#8217;d be getting only 0.06 of the power output (if the element is rated at 1200 watts I&#8217;d be getting about 75 watts &#8211; if it&#8217;s rated at an unlikely 3kw I would be getting about 180 watts) but 50 litres in a proper insulated tank won&#8217;t need all that much power to warm up. What I will need to do is to find a way of fitting a temperature sensor in there so that I can keep an eye on the temperature.<\/p>\n<p>Of course, it might not work. But the whole idea is that it&#8217;s an experiment and we can see what happens.<\/p>\n<p>But I had a bad night last night. I woke up at about 04:00 with a nightmare (a long time since I&#8217;ve had one of those) and I couldn&#8217;t go back to sleep afterwards. I&#8217;ll be having an early night.<\/p>\n<div class='watch-action'><div class='watch-position align-left'><div class='action-like'><a class='lbg-style1 like-632 jlk' href='javascript:void(0)' data-task='like' data-post_id='632' data-nonce='7faa308a29' rel='nofollow'><img class='wti-pixel' src='https:\/\/lesguis.com\/wp\/wp-content\/plugins\/wti-like-post\/images\/pixel.gif' title='Like' \/><span class='lc-632 lc'>+2<\/span><\/a><\/div><div class='action-unlike'><a class='unlbg-style1 unlike-632 jlk' href='javascript:void(0)' data-task='unlike' data-post_id='632' data-nonce='7faa308a29' rel='nofollow'><img class='wti-pixel' src='https:\/\/lesguis.com\/wp\/wp-content\/plugins\/wti-like-post\/images\/pixel.gif' title='Unlike' \/><span class='unlc-632 unlc'>-1<\/span><\/a><\/div> <\/div> <div class='status-632 status align-left'><\/div><\/div><div class='wti-clear'><\/div>\n    <p style=\"background-color: #f7e7b7; padding: 8px; margin-top: 1em; font-size: 0.95em;\">\n        IMPORTANT NOTE: From 1 September 2026 this blog has a live blog feature for the latest news.\n        Click any post title with \"LIVE\" in it to see live updates. Comments are welcome from logged-in users and must be approved before they appear.\n    <\/p>","protected":false},"excerpt":{"rendered":"<p>The plasterboarding on the two outside walls in the bedroom is only up to 2.50 metres whereas the room itself is about 2.78. What I&#8217;ve done in the gaps is to run all of the conduit and trunking for the electric cables, as you may have already seen. For the side wall, I can make [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[504,44,4507,1616,67,258],"tags":[463,4788,5398,212,264,2560,5565,618,6741,470,5295,5366,521,304,372,584],"class_list":["post-632","post","type-post","status-publish","format-standard","hentry","category-bill-dudgeon","category-dream","category-eric-hall-2","category-france","category-le-quartier","category-les-guis","tag-12-volt-domestic-circuit","tag-bad-night","tag-bill-dudgeon","tag-dream","tag-electricity","tag-eric-hall","tag-france","tag-hound-of-the-baskervilles","tag-immersion-heater","tag-insulation","tag-le-quartier","tag-les-guis","tag-plasterboard","tag-sawmill","tag-space-blanket-insulation","tag-tongue-and-groove"],"_links":{"self":[{"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=\/wp\/v2\/posts\/632","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=632"}],"version-history":[{"count":2,"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=\/wp\/v2\/posts\/632\/revisions"}],"predecessor-version":[{"id":5784,"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=\/wp\/v2\/posts\/632\/revisions\/5784"}],"wp:attachment":[{"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=632"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=632"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lesguis.com\/wp\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=632"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}